Symmetricom TimeProvider 1000 User Manual page 117

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Description of Alarm
Alarm ID
Condition
BTBACK
All BesTime backup
UP
sources are unusable
to the BesTime engine
IOCFAIL
Summary alarm of IOC
failures; for example,
calibration was unsuc-
cessful
CLKWARM
Local oscillator on the
specified IOC is in
Warm-up mode
CLKFREE
Local oscillator on
specified IOC is in
Free-run mode
CLKBRDG
Local oscillator on
specified IOC is in
Bridging mode
CLKHOLD
Local oscillator on
specified IOC is in
Holdover mode
SYNTHEOR
The synthesizer has
reached the defined End
of Range for the
oscillator type in the IOC
ANTCOMM
Loss of communications
to the antenna
GPSPOS
Position of the antenna
is unknown
GPSPWR
Power to the TPIU is too
high or too low
GPSSYS
Error with startup test,
TRAIM, and/or UTC/
Ephemeris data
GPSTRK
GPS engine is not
tracking satellites
INPDISQ
Specified input has
been disqualified or
qualified as a possible
system reference.
097-58001-02 Revision C – August 2005
Possible
Error
Alarm
Delay
Levels
Default
IMMED
MN | MJ |
IMMED
CR
MN | MJ
IMMED
MN | MJ |
IMMED
CR
MN | MJ |
IMMED
CR
MN | MJ |
IMMED
CR
IMMED
<aid> = GPS
IMMED
IMMED
IMMED
IMMED
IMMED
MN | MJ |
FLT
CR
DELAY
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Default Level
Error
Delay
SSU
Editable?
Mode
No
NA
No
MJ
No
MN
No
MJ
No
MJ
No
MJ
No
MJ
No
MN
Yes
NA
No
MN
Yes
MN
Yes
MN
Yes
MN
TimeProvider User's Guide 117
SUB
Mode
NA
MJ
MN
MJ
MJ
MJ
MJ
MN
NA
MN
MN
MN
MN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1100

Table of Contents