Table 6-5. Event Codes (Continued)
Event ID
Description
RESET
The IMC has been
reset by user
command
SIDCHG
The source ID has
changed in the
database
UIDCHG
A user's name has
changed in the
database
USRADD
A user has been
added to the
database
USRDEL
A user has been
deleted from the
database
XFERFAIL
Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the
redundant IOC was
not successful
XFEROK
Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the
redundant IOC was
successful
CLKTYPE
The specified IOC
clock has been set to
the specified value.
This value is used to
define the IOCs
pull-in range and
SSM generation in
Holdover mode
097-58001-02 Revision C – August 2005
Keyword
AID
TYPE
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
IOC Event Codes
EQPT
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Default Value/
Description of Values
Keyword
n/a
n/a
n/a
20-character name used to
identify the network
element
uid
User Identification – up to
20 characters
uid
uid – assigned user name
pid
pid – assigned user
password
uap
uap – assigned user access
level
uid
uid – username
n/a
n/a
n/a
n/a
TYPEI
ST3E | TYPE I
ST2 | TYPE II
TimeProvider User's Guide 159