Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Table 6-7. Alarms (Continued)
Alarm ID
Alarm Condition
Or
Description
CONDTYPE
INPFRQ
The specified input
port's calculated
received frequency is
exceeding the pull-in
range of the local
oscillator. The received
signal's calculated
frequency alarmed
condition disqualifies
the input as a possible
reference. After
INPFRQ is set, the
alarm clears when the
input frequency is within
the defined pull-in range
limits.
INPPHASE
The specified input port
has a excessive phase
measurement that is
disqualifies it from being
used.
INPQL
Alarm indicating the
received SSM is of
lesser quality than the
Local Oscillator's
QLEVEL for a specified
input.
INPTRR
The specified input port
has a Tip/Ring reversal
on it's connection to the
system.
EXDSC
Input has had excessive
discontinuities. This is
indicated when there are
more than 3 signal faults
of the same type within a
5 minute window. The
alarm clears when the 5-
minute window contains
less than 3 alarms of the
same type.
MTIE
Input has exceeded at
least one of the MTIE
alarm thresholds.
176 TimeProvider User's Guide
Error
AID
Service
Delay
TYPE
Affecting
Default
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
T1
NSA
IMMED
Alarm Default
Error
Level
Delay
Editable
SSU PRS SUB
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
NO
MN
MN
097-58001-02 Revision C – August 2005
NR
MN
MN
MN
MN
MN