Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Description of Alarm
Alarm ID
Condition
INPLOS
Specified input has
Loss Of Signal.
INPPHASE
Specified input port's
phase measurement
exceeds usable value.
EXDSC
Input has had excessive
discontinuities, indicated
by more than 3 signal
faults of the same type
within a 5-minute period.
The alarm clears when
the 5-minute window
contains less than 3
alarms of the same type.
FFOFF
Input has exceeded
FFOFF threshold
MTIE
Input has exceeded at
least 1 of the MTIE
alarm thresholds
TPIUSIG
Composite timing
signal interface is not
functionin
INPDISQ
Specified input has
been disqualified or
qualified as a possible
system reference.
INPLOS
Specified input has
Loss Of Signal.
INPFRQ
Specified input has
calculated received
frequency that exceeds
the pull-in range of the
LO.This alarm condition
disqualifies the input as
a possible reference.
INPPHASE
Specified input port's
phase measurement
exceeds usable value.
118 TimeProvider User's Guide
Possible
Alarm
Levels
MN | MJ |
IMMED
CR
1
NR | NA |
IMMED
MN | MJ |
CR
NR | NA |
IMMED
MN | MJ |
CR
IMMED
IMMED
IMMED
<aid> = PRS
MN | MJ |
FLT
CR
DELAY
MN | MJ |
IMMED
CR
2
NR | NA |
IMMED
MN | MJ |
CR
3
NR | NA |
IMMED
MN | MJ |
CR
Error
Error
Delay
Delay
Default
Editable?
No
No
No
No
No
No
Yes
No
No
No
097-58001-02 Revision C – August 2005
Default Level
SSU
SUB
Mode
Mode
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
NR
MN
MN

Advertisement