Table 6-5. Event Codes (Continued)
Event ID
Description
ALMCHG
The IMC alarm
parameters have
changed
AOMERGE
Enable/Disable
autonomous event
generation for the
current session
BAUD
The IMC serial port
baud rate has
changed
CMDCHG
The command
access level has
changed
ECHO
The current sessions'
echo setting has
changed
FLOW
The IMC serial port
flow control has
changed
FWFAIL
Firmware upgrade of
IMC or IOC was not
successful
FWOK
Firmware upgrade of
IMC or IOC was
successful
097-58001-02 Revision C – August 2005
Keyword
AID
TYPE
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Default Value/
Description of Values
Keyword
N/A
Alarm keywords and values
are listed in
When the user changes a
value, the ALMCHG event
is generated and contains
the keyword and value
ENABLE
ENABLE – Autonomous
messages are displayed in
the current session
DISABLE – Autonomous
messages are not
displayed in the current
session
9600
2400 | 9600 | 19200 | 28800
| 38400 | 57600
ACCLVL-USER
NONE | USER | ADMIN |
SECURITY
DISABLE
ENABLE – User's
keystrokes are echoed
DISABLE – User's
keystrokes are not echoed
NONE
NONE – No flow control
SW – Software flow control
XON/XOFF
HW – Hardware flow
control CTS/RTS
SWHW – Both hardware
and software flow control
used
n/a
n/a
n/a
n/a
TimeProvider User's Guide 157