Chapter 7 Specifications of the TimeProvider
T1 Retimer
Table 7-4. Output Signal Specifications (Continued)
Parameter
Amplitude
Termination Impedance
Amplitude
Termination Impedance
Amplitude
Termination Impedance
Amplitude
Termination Impedance
Amplitude
Termination Impedance
Amplitude
Termination Impedance
T1 Retimer
The T1 Retimer module has the following specifications:
Table 7-5. T1 Retimer Specifications
Parameter
Specifications
Input Amplitude Range
Termination Impedance
192 TimeProvider User's Guide
CC Signals
2.7 to 3.3 V
p
133 Ω ± 5% balanced
JCC Signals
1.0 V
±0.1 V
p
110 Ω balanced
JCC4 Signals
1.0 V
±0.1 V
p
110 Ω balanced
8k Signals
4 V p-p ± 10%
100 Ω balanced
1.544 MHz Signals
0 dBm ± 3 dB
75 Ω unbalanced
6.312 MHz Signals
0 dBm ± 3 dB
75 Ω unbalanced
ANSI T1.101 and Telcordia GR-1244
+3 to –24 dB DSX
100 Ω ±5% balanced
Specification
Specification
097-58001-02 Revision C – August 2005