Symmetricom TimeProvider 1000 User Manual page 175

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Table 6-7. Alarms (Continued)
Alarm ID
Alarm Condition
Or
Description
CONDTYPE
INPLOS
The specified input port
has Loss Of Signal.
When LOS is detected,
the input is removed
from the possible
reference list. The LOS
must be continuously
present for the Fault
Delay Time (FLTDELAY)
before disqualifying the
input as a possible
reference. After INPLOS
is set, the alarm clears
when the input signal is
LOS free for the Clear
Delay Time
(CLRDELAY).
INPOOF
The specified input port
is receiving an Out Of
Frame signal. When
OOF is detected, the
input is removed from
the possible reference
list. The OOF must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPOOF is set, the
alarm clears when the
input signal is OOF free
for the Clear Delay Time
(CLRDELAY).
097-58001-02 Revision C – August 2005
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Error
AID
Service
Delay
TYPE
Affecting
Default
T1
NSA
IMMED
T1
NSA
IMMED
Troubleshooting the TimeProvider
Alarm Default
Error
Level
Delay
Editable
SSU PRS SUB
NO
MN
MN
NO
MN
MN
TimeProvider User's Guide 175
MN
MN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1100

Table of Contents