Siemens SINAMICS G120 Function Manual page 31

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

The SBC safety function is standardized
The SBC function is defined in IEC/EN 61800-5-2:
"The SBC function supplies a safe output signal to control an external brake."
The SBC inverter function complies with what is defined in the standard.
Application example for the SBC function
Example
After a hoisting gear stops, the inverter must close
the brake in order to minimize the risk of the load
falling.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 04/2014, FW V4.7, A5E34261271B AA
3.8 Safe Brake Control (SBC)
Possible solution
Connect the motor holding brake to the
inverter via Safe Brake Relay.
Select STO when the drive stops.
Description
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents