Deselecting SLS after a discrepancy
Procedure
To deselect SLS, proceed as follows:
1. Remove the discrepancy.
2. Acknowledge the discrepancy message with the fail-safe acknowledge signal via a safety
3. Acknowledge the inverter with the "standard" acknowledge signal.
You have acknowledged the discrepancy message and deselected SLS.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 04/2014, FW V4.7, A5E34261271B AA
input: F-DI = 0 → 1 → 0.
Alternatively, you can acknowledge the message in one of the following ways. However,
the drive stops in these cases:
– Select the STO function and then deselect again: F-DI = 1 → 0 → 1.
– Select the SS1 function and then deselect again: F-DI = 1 → 0 → 1.
– Switch off the inverter supply voltage and on again (power on reset).