Parker EME
3.7.3.1
Wiring of digital outputs
Compax3
F1
F2
24V
X12/1
X12/11
X12/2
18.2K W
0V
X12/15
The circuit example is valid for all digital outputs!
The outputs are short circuit proof; a short circuit
generates an error.
F1: delayed action fuse
F2: quick action electronic fuse; can be reset by switching the 24VDC supply off and on again.

Connection of the digital Outputs/Inputs

SPS/
PLC
192-120101 N11 C3I11T11 November 2007
Status of digital inputs
Compax3
SPS/PLC
X12/1
X12/6
10nF
X12/15
The circuit example is valid for all digital inputs!
Signal level:
> 9.15V is detected "1"
> 8.05V is detected "0"
Compax3 device description
F2
F1
100K W
22K W
22K W
22K W
10K W
59
24V
0V