Parker EME
3.3.6.3
Caution!

Connection of the power voltage of 2 C3S 3AC devices

The power voltage DC of the single phase Compax3 servo axes must not be
In order to improve the conditions during brake operation, the DC power voltage of
2 servo axes may be connected.
The capacity as well as the storable energy are increased; furthermore the braking
energy of one servo axis may be utilized by a second servo axis, depending on the
application.
It is not permitted to connect the power voltage in order to
use one brake circuit for two servo axes, as this function
cannot be ensured reliably.
Note the following:
Caution! In case of non-compliance with the following instructions, the
device may be destroyed!
You can only connect two similar servo axes (same power supply; same rated
currents)
Connected servo axes must always be fed separately via the AC power supply.
If the external pre-fuse of one of the servo axes takes action, the second servo axis
must also be disconnected automatically.
Please connect as follows:
Servo axis 1 X2/4 to servo axis 2 X2/4
Servo axis 1 X2/5 to servo axis 2 X2/5
192-120101 N11 C3I11T11 November 2007