Compax3 device description
3.3.2.
Connector and pin assignment C3S
Overview:
24
Caution!
When the control voltage is missing there is no indication whether or
not high voltage supply is available.
PE connection
The PE connection is made with 10mm
bottom of the device.
Attention hot surface!
The heat dissipator can reach very high temperatures (>70°C)
Line cross sections of the line connections X1, X2, X3
Compax3 device:
S025V2, S063V2
S100V2, S150V2
S015V4, S038V4, S075V4, S150V4
S300V4
AC - Versorgung
AC - Supply
DC - Versorgung
DC - Supply
Freigabe 24VDC
Enable 24VDC
Further information on the assignment of the plug mounted at the particular
192-120101 N11 C3I11T11 November 2007
2
via a grounding screw at the
Cross-section: Minimum... Maximum[mm
0,25 ... 2.5 (AWG: 24 ... 12)
0,25 ... 4 (AWG: 24 ... 10)
0,5 ... 6 (AWG: 20 ... 7)
Compax3
X1
X10
X4 (24VDC)
X4/3
device can be found below!
Positioning via digital I/Os
2
]
RS232
PC
SSK1