Mounting and dimensions C3H

Dimensions:
Ventilation:
In this chapter you can read about:
Mounting distances, air currents Compax3H050V4 ..........................................................................66
Mounting distances, air currents Compax3H090V4 ..........................................................................66
Mounting distances, air currents Compax3H1xxV4...........................................................................67
The devices must be mounted vertically on a level surface in the control cabinet.
C3H050V4
453mm
C3H090V4
668.6mm
C3H1xxV4
720mm
Mounting: 4 screws M6
During operation, the device radiates heat (power loss). Please provide for a
sufficient mounting distance below and above the device in order to ensure free
circulation of the cooling air. Please do also respect the recommended distances of
other devices. Make sure that the mounting plate is not exhibited to other
temperature influences than that of the devices mounted on this very plate.
If two or more devices are combined, the mounting distances are added.