Compax3 device description
3.8.5.

Mounting and dimensions C3MP/C3M

Ventilation:
Information on
360mm
64
During operation, the device radiates heat (power loss). Please provide for a
sufficient mounting distance below and above the device in order to ensure free
circulation of the cooling air. Please do also respect the recommended distances of
other devices. Make sure that the mounting plate is not exhibited to other
temperature influences than that of the devices mounted on this very plate.
The devices must be mounted vertically on a level surface. Make sure that all
devices are sufficiently fixed.
Compaxa3MP and Compax3M are force-ventilated via a ventilator fan fixed to
the lower part of the heat dissipator!
Mounting spacing: At the top and below: at least 100mm
C3MP (mains module)
C3MP10D6
Mounting:
2 socket head screws M5
263mm
50mm
Tolerances: DIN ISO 2768-f
192-120101 N11 C3I11T11 November 2007
C3M (axis)
C3M050D6
C3M100D6
C3M150D6
50,5mm
46mm
Positioning via digital I/Os
90°
400mm