Software End Limits - Parker Compax3S025V2 Operating Instructions Manual

Compax3 i11t11 positioning via digital i/os
Hide thumbs Also See for Compax3S025V2:
Table of Contents

Advertisement

Setting up Compax3
4.1.7.5
90
The machine reference offset is used to determine the actual reference point for
positioning.
That is: Zero point = Machine zero + Machine zero offset
Note: If the machine zero proximity switch is at the positive end of the travel range,
the machine zero offset must be = 0 or negative.
A change in the machine reference offset does not take effect until the next

Software end limits

The travel range is defined via the negative and positive end limits.
0
1
2
1: negative end limit
2: positive end limit
Software end limit in absolute operating mode
The positioning is restricted to the range between the travel limits.
1
V
1: negative end limit
2: positive end limit
The reference is the position reference point that was defined with the machine
reference and the machine reference offset.
Software end limits in reset mode
The reset mode does not support software end limits
Software end limit in continuous mode
Each individual positioning is confined within the travel limits.
The reference is the respective current position.
192-120101 N11 C3I11T11 November 2007
machine reference run.
2
Gearing, ...
Jog
Positioning via digital I/Os

Advertisement

Table of Contents