Setting up Compax3

4.1.12. Error response

4.1.13. Configuration name / comments

104
Under "configuring: Under "configuration: error reaction" you can change the error
reaction for individual errors (see page 243) (the error no. which can be influenced
is displayed).
Possible settings for the error reaction are:
No response
downramp / stop
Downramp / stromlos schalten (standard setting)
Note on Compax3H:
The error reaction upon the "low voltage DC" error (0x32229 is fixed to
"downramp/deenergize" for Compax3H.
Here you can name the current configuration as well as write a comment.
Then you can download the configuration settings or, in T30 or T40 devices,
perform a complete Download (with IEC program and curve).
Caution!
Deactivate the drive before downloading the configuration software!
N.B.!
Incorrect configuration settings entail danger when activating the drive.
Therefore take special safety precautions to protect the travel range of
the system.
Mechanical limit values!
Observe the limit values of the mechanical components!
Ignoring the limit values can lead to destruction of the mechanical
components.
192-120101 N11 C3I11T11 November 2007
Positioning via digital I/Os