Oscilloscope operating mode switch:

Oscilloscope operating mode switch:
Selection of the desired operating mode: SINGLE, NORMAL; AUTO and ROLL by
clicking on this button.
Changing the operating mode is also permitted during a measurement. The current
measurement is interrupted and started again with the changed settings.
The following operating modes are possible:
Operating mode
Short description
SINGLE
Single measurements of 1-4 channels with trigger on a freely
selectable channel
NORMAL
Like Single, but after each trigger event, the measurement is
started again.
AUTO
No Trigger. Continuous measuring value recording with the
selected scanning time or XDIV setting
ROLL
Continuous measuring value recording of 1 .. 4 channels with
selectable scanning time and a memory depth of 2000 measuring
values per channel.
With SINGLE / NORMAL / AUTO, the meansurement is made in Compax3 and is
then loaded into the PC and displayed.
With ROLL, the measuring values are loaded into the PC and displayed
continuously.