Figure 69: Installing An Ac Power Supply In An Ex4300 Switch - Juniper EX4300 Hardware Manual

Hide thumbs Also See for EX4300:
Table of Contents

Advertisement

EX4300 Switch Hardware Guide
234
NOTE:
Each power supply must be connected to a dedicated power source
outlet.
The power supply slots are at the right end of the rear panel on 24-port and
48-port switches, and at the left end on 32-port switches.
Figure 69 on page 234
48-port switches. The procedure is the same for 32-port switches.
To install an AC power supply in the switch:
Ensure that you have the correct power supply. The label
1.
on the power supply must match the label
(AFO)
the installed fan module.
Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD
2.
point on the chassis.
If the power supply slot has a cover panel on it, loosen the captive screws on the cover
3.
panel by using your fingers or the screwdriver. Hold the captive screw and gently pull
it outward to remove the cover panel. Save the cover panel for later use.
Taking care not to touch power supply pins, leads, or solder connections, remove the
4.
power supply from the bag.
Using both hands, place the power supply in the power supply slot on the rear panel
5.
of the switch and slide it in until it is fully seated and the ejector lever fits into place.

Figure 69: Installing an AC Power Supply in an EX4300 Switch

NOTE:
If you have a Juniper J-Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
shows how to install an AC power supply in 24-port or
AIR IN (AFI)
Copyright © 2017, Juniper Networks, Inc.
AIR IN (AFI)
or
AIR OUT
or
on
AIR OUT (AFO)
. Failure