Connecting Dc Power To An Ex4300 Switch - Juniper EX4300 Hardware Manual

Hide thumbs Also See for EX4300:
Table of Contents

Advertisement

EX4300 Switch Hardware Guide
Related
Documentation

Connecting DC Power to an EX4300 Switch

188
ready: the power supplies or a cover panel must be installed in the switch to ensure
proper airflow.
CAUTION:
We recommend that you install either a replacement power
supply or a cover panel in the empty power supply slot to prevent chassis
overheating and dust accumulation.
AC Power Supply in EX4300 Switches on page 49
AC Power Supply LEDs in EX4300 Switches on page 56
EX4300 switches can be configured with up to two DC power supplies. After you install
at least one power supply, you can connect power to the switch.
CAUTION:
Do not mix:
AC and DC power supplies in the same chassis
Power supplies with different airflow labels (
) in the same chassis.
(AFO)
Fan modules with different airflow labels (
in the same chassis.
Power supplies and fan modules with different airflow labels (
and
AIR OUT (AFO)
Before you begin connecting DC power to an EX4300 switch:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage (see
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you have connected the switch chassis to earth ground.
CAUTION:
Ensure that you install the power supply module first and then
install the DC input wire, before closing input breaker ON.
CAUTION:
Before you connect power to the device, a licensed electrician
must attach a cable lug to the grounding and power cables that you supply.
A cable with an incorrectly attached lug can damage the device (for
example, by causing a short circuit).