N+0 Redundancy Configuration Of Ac Power Supplies; Table 29: N+0 Ac Power Calculations For 24-Port Ex4300 Switches - Juniper EX4300 Hardware Manual

Hide thumbs Also See for EX4300:
Table of Contents

Advertisement

EX4300 Switch Hardware Guide

N+0 Redundancy Configuration of AC Power Supplies

Table 29: N+0 AC Power Calculations for 24-Port EX4300 Switches

Power Supply Rating
PSU
PSU
0
1
350 W AC
350 W AC
350 W AC
350 W AC
715 W AC
715 W AC
715 W AC
715 W AC
715 W AC
1100 W AC
1100 W AC
1100 W AC
1100 W AC
1100 W AC
350 W AC
52
In an N+0 redundancy configuration, lower priority PoE ports may be impacted if a power
supply fails.
Depending on the power supplies installed in the switch, you can determine the system
power budget.
If one power supply is installed in the switch:
System power budget = Output wattage of the installed power supply (PSU(W))
If two power supplies are installed in the switch:
System power budget = (Sum of the output wattages of the two power supplies) –
(10% of the output wattage of the power supply that has the higher output wattage)
System power budget = PSU
Table 29 on page 52
lists the N+0 power calculation for 24-port EX4300 switches that
use 350 W AC, 715 W AC, and 1100 W AC power supplies.
Total Power
(in watts)
PSU
(W) +
0
PSU
(W)
1
350
700
1065
715
1430
1815
1100
2200
1450
Table 30 on page 53
lists the N+0 power calculation for 32-port EX4300 switches that
use the 350 W AC power supply.
(W) + PSU
(W) – (0.10 x MAX (PSU
0
1
System
Backup
Power
Power
Base
Budget (in
(in
Power (in
watts)
watts)
watts)
350
0
150
665
0
150
993.5
0
150
715
0
150
1358.5
0
150
1705
0
150
1100
0
150
2090
0
150
1340
0
150
(W), PSU
(W))
0
1
Available
Ports
PoE Power
Enabled
(in watts)
for PoE+
200
6
515
17
720
24
565
18
720
24
720
24
720
24
720
24
720
24
Copyright © 2017, Juniper Networks, Inc.