EX4300 Switch Hardware Guide
216
Using the CLI, set the following parameter values in the console server or PC:
Baud rate—9600
Flow control—None
Data—8
Parity—None
Stop bits—1
DCD state—Disregard
To connect and configure the switch from the console by using the CLI:
Connect the console port to a laptop or PC by using the RJ-45 to DB-9 serial port
1.
adapter. An Ethernet cable that has an RJ-45 connecter at either end and an RJ-45
to DB-9 serial port adapter are supplied with the switch.
For the location of the console port on different EX Series switches:
See EX2200 Switches Hardware Overview.
See EX2300 Switches Hardware Overview.
See Rear Panel of an EX3200 Switch.
See Rear Panel of an EX3300 Switch.
See Rear Panel of an EX3400 Switch.
See Rear Panel of an EX4200 Switch.
See
"EX4300 Switches Hardware Overview" on page 3
See Front Panel of an EX4500 Switch.
See EX4550 Switches Hardware Overview
See Switch Fabric and Routing Engine (SRE) Module in an EX6200 Switch.
See Switch Fabric and Routing Engine (SRE) Module in an EX8208 Switch.
See Routing Engine (RE) Module in an EX8216 Switch.
NOTE:
In EX2200-C, EX2300, EX3400, EX4300, and EX4550 switches,
you can also use the Mini-USB Type-B console port to connect to a laptop
or PC. See
"Connecting an EX Series Switch to a Management Console by
Using the Mini-USB Type-B Console Port" on page
At the Junos OS shell prompt
2.
Enter the hostname. This is optional.
3.
root%
, type ezsetup.
Copyright © 2017, Juniper Networks, Inc.
195.