AROUND THE DRUM
28 April 2005
6.4.5 CLEANING THE DRUM
This machine uses a counter blade system
[A]
to clean toner from the photoconductive
surface of the drum. !
In a counter blade system, the cleaning
blade [A] is mounted opposed to the
direction of drum rotation.
B188D922.WMFF
The counter blade has a pressure
release lever which can be moved easily
[A]
between the opened [A] and closed [B]
position to release it from the drum. The
blade must be released before the drum
is removed from the machine.
[B]
B188D923.WMFF