Ricoh Aficio 480W Dolphin-C2 Service Manual page 248

Table of Contents

Advertisement

28 April 2005
5802
Engine Free Run
Makes a base engine free run.
Note: The machine automatically leaves free run mode after the machine leaves the
SP mode or after the machine is cycled off and on.
[0~1/1]
0: Disable: Release free run mode
1: Enable: Enable free run mode
5803 Input Check
5804 Output Check
5811 Machine Serial Number
5812
Service Tel. No. Setting
001 Service
002 Facsimile
003 Supply
004 Operation
5816
Remote Service
001 I/F Setting
002 CE Call
003 Function
Flag
006 Device
Information
Call Display
007 SSL Disable
SP (SERVICE PROGRAM) MODE TABLES
Copier Engine Free Run
Allows you to test component input (☛5.8)
Allows you to test component output (☛5.9)
The serial number is set with this code before
shipping.
Inputs the telephone number of the CE (displayed when a
service call condition occurs.)
Input the fax number of the CE.
These SP codes allow you to enter the telephone numbers to
be displayed for the supply and operation support centers in
the User Tools mode.
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
Lets the customer engineer start or end the remote machine
check with CSS or NRS; to do this, push the center report
key.
Enables and disables remote diagnosis over the NRS
network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
Controls if the item for initial setting of the screen for the
NRS device-information notification-call is shown.
[0~1/1]
0: Enabled. Item initial setting not shown.
1: Disable. Item for initial setting shown.
Controls if RCG (Remote Communication Gate)
confirmation is done by SSL during an RCG send for the
NRS over a network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
5-71

Advertisement

Table of Contents
loading

Table of Contents