Ricoh Aficio 480W Dolphin-C2 Service Manual page 39

Table of Contents

Advertisement

28 April 2005
13. Open the upper unit [A] and confirm that the
drum is covered with toner.
14. Push the pressure lever [B] to the right to
push the cleaning blade against the drum,
then close the upper unit.
15. To initialize the ID sensor, touch "SP Direct",
push [#], enter SP3001 002 then touch
[Execute].
Wait about 12 seconds for initialization to
complete.
16. When the message prompts you that the
operation is finished, touch "Exit".
17. Exit the SP mode and make copy samples.
NOTE: Ask the customer about their copy volume. If the average copy volume is
high (2.5 km/month, 200 m/day, or more), then you must change SP 2201
004 to High Duty Mode to prevent toner scattering.
[A]
[B]
1-17
COPIER (B188)
B010I521.WMF

Advertisement

Table of Contents
loading

Table of Contents