Platform Components
2-5
Platform Overload Recovery
Message (software V2.04 and
later)
If the ground controls LCD screen displays
OVERLOAD RECOVERY, the emergency lowering
system has been used while the platform was
overloaded.
How to Clear the Platform
Overload Recovery Message
Note: This message shall be cleared by a person
trained and qualified on the troubleshooting and
repair of this machine.
Note: Use the following chart to identify the
description of each LCD screen control button used
in this procedure.
Plus
Minus
1
Turn the key switch to the off position.
2
Press and hold the enter button on the ground
control panel while turning the key switch to
ground controls. Hold the enter button for
approximately 5 seconds.
36
Previous
Enter
3
Press the buttons on the ground controls in the
following sequence:
(plus)(minus)(minus)(plus).
4
Press the enter or previous button on the
LCD screen until CLEAR OVERLOAD
RECOVERY is displayed.
5
Press the plus button or the minus button to
select YES. Then press the buttons in the
following sequence:
(plus)(plus)(plus)(minus). and press the
enter button to accept.
Note: The passcode buttons
(plus)(plus)(plus)(minus) must be entered in the
proper sequence before the enter button is
pressed.
6
Press the enter or previous button on the
LCD screen until EXIT is displayed.
7
Press the plus button or minus button to
select YES and then press the enter button.
8
Turn the key switch to the off position.