Genie Z-80/60 Service And Repair Manual page 151

Hide thumbs Also See for Z-80/60:
Table of Contents

Advertisement

September 2016
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523717
12
125
Timeout Error of
CAN-Transmit-Frame AmbCon;
Weather environments
523718
3
1488 SCR mainrelay; short circuit to
battery (only CV56B)
523718
4
1489 SCR mainrelay; short circuit to
ground (only CV56B)
523718
5
1486 SCR mainrelay; open load (only
CV56B)
523718
12
1487 SCR mainrelay; powerstage over
temperature (only CV56B)
523766
9
281
Timeout Error of
CAN-Receive-Frame Active
TSC1AE
523767
9
282
Timeout Error of
CAN-Receive-Frame Passive
TSC1AE
523768
9
283
Timeout Error of
CAN-Receive-Frame Active
TSC1AR
523769
9
284
Timeout Error of
CAN-Receive-Frame Passive
TSC1AR
523770
9
285
Timeout Error of
CAN-Receive-Frame Passive
TSC1DE
523776
9
291
Timeout Error of
CAN-Receive-Frame TSC1TE -
active
523777
9
292
Passive Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
523778
9
293
Active Timeout Errorof
CAN-Receive-Frame TSC1TR
523779
9
294
Passive Timeout Error of
CAN-Receive-Frame TSC1TR
Part No. 1268556
Deutz D 2.9 L4 Engine Fault Codes
SPN
FMI KWP Description
523788
12
523793
9
523794
9
523895
13
523896
13
523897
13
523898
13
523910
6
523913
3
523913
4
523914
3
523914
4
523914
5
523914
5
523914
11
523914
12
523919
2
523920
2
Service and Repair Manual
299
Timeout Error of
CAN-Transmit-Frame TrbCH;
Status Wastegate
202
Timeout Error of
CAN-Receive-Frame UAA10;
AGS sensor service message
203
Timeout Error of
CAN-Receive-Frame UAA11;
AGS sensor data
559
Check of missing injector
adjustment value programming
(IMA) injector 1 (in firing order)
560
check of missing injector
adjustment value programming
(IMA) injector 2 (in firing order)
561
check of missing injector
adjustment value programming
(IMA) injector 3 (in firing order)
562
check of missing injector
adjustment value programming
(IMA) injector 4 (in firing order)
1261 Air Pump; over current
74
Sensor error glow plug control
diagnostic line voltage; signal
range check high
75
Sensor error glow plug control
diagnostic line voltage; signal
range check low
78
Glow plug control; short circuit to
battery
79
Glow plug control; short circuit to
ground
76
Glow plug control; open load
1216 Glow plug control release line;
short circuit error
1217 Glow plug control; internal error
77
Glow plug control; powerstage
over temperature
1378 Sensor air pump airpressure;
plausibility error
1379 Sensor exhaust gas back
pressure burner; plausibility error
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents