Valve Coils - Genie Z-80/60 Service And Repair Manual

Hide thumbs Also See for Z-80/60:
Table of Contents

Advertisement

September 2016
8-14

Valve Coils

How to Test a Coil
A properly functioning coil provides an
electromotive force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil that provides this force field.
Since coil resistance is sensitive to temperature,
resistance values outside specification can produce
erratic operation. When coil resistance decreases
below specification, amperage increases. As
resistance rises above specification, voltage
increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1
Tag and disconnect the wiring from the coil to
be tested.
2
Test the coil resistance.
Result: The resistance should be within
specification, plus or minus 30%.
Result: If the resistance is not within
specification, plus or minus 30%, replace the
coil.
Part No. 1268556
Valve Coil Resistance
Specification
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / 10°C
that your air temperature increases or decreases
from 68°F / 20°C.
Valve Coil Resistance Specification
Proportional solenoid valve, 12V DC
(schematic items G, W and AB)
Proportional solenoid valve, 12V DC
(schematic items R)
3 position 4 way solenoid valve, 12V DC
(schematic items BA, BB, CA, CB, CP, CQ,GB,
GP and GQ)
3 position 4 way solenoid valve, 10V DC
(schematic items O and S)
2 position 2 way solenoid valve, 10V DC
(schematic items J)
2 position 2 way solenoid valve, 10V DC
(schematic items C and P)
2 position 3 way solenoid valve, 10V DC
(schematic items H, V, X, Z, AA, EE and EF)
2 position 3 way solenoid valve, 12V DC
(schematic items BC, BD, CE, CF, FB and FC)
Service and Repair Manual
Manifolds
4.8 Ω
6.3 Ω
3.3 Ω
6.3 Ω
6.3 Ω
9 Ω
9 Ω
9 Ω
113