System
Code Fault Name
EGO
134
EGO Open/Lazy Pre-cat 1
Sensors
154
EGO Open/Lazy Post-cat 1
Injectors
261
Injector Loop Open or
Low-Side Short to Ground
262
Injector Coil Shorted
Power Relay
686
Relay Control Ground
Control Coil
Short
685
Relay Coil Short
687
Relay Coil Short to Pwr
Tach
2618
Tach Output Ground Short
Output
2619
Tach Output Short to Pwr
EPR
1171
EPR Delivery Pressure >
Diagnostics
than expected
LPG
1172
EPR Delivery Pressure <
than expected
1173
EPR Comm Lost
1174
EPR Voltage Supply High
1175
EPR Voltage Supply Low
1176
EPR Internal Actuator
fault detection
1177
EPR Internal Circuitry fault
detection
1178
EPR Internal Comm fault
detection
1 = Shutdown
2 = AL disable
Part No. 1268556
Continental TME27 Engine Fault Codes
1 2 3 4 5 6 Fault Conditions
Y Y
Y Y
n Y Y Y
Y Y Y
Y
Y
Y
Y
Y
Y
n Y
n Y
3 = AL disable key-cycle
4 = Power derate 1
Service and Repair Manual
EGO cold persistently > 120 seconds
EGO cold persistently > 120 seconds
Injector off-state low-side < 4 vdc and battery
voltage > 9 vdc
Injector on-state low-side > 4 vdc and battery
voltage < 16 vdc
Does not turn on MIL
Does not turn on MIL
Y
MJ actual-commanded press > 4 in. H20
Y
MJ actual-commanded press < 4 in. H20
Y
No MJ packets received within 500 ms
Y
Y
Y
Y
Y
5 = Power derate 2
6 = Low rev limit
149