How To Adjust The Secondary Boom Down Relief Valve - Genie Z-80/60 Service And Repair Manual

Hide thumbs Also See for Z-80/60:
Table of Contents

Advertisement

Service and Repair Manual
Manifolds
How to Adj ust the Sec ondary Boom D own Relief Val ve
How to Adjust the Secondary
Boom Down Relief Valve
Note: Refer to Function Manifold Component list to
locate the secondary boom down relief valve.
1
Connect a 0 to 5000 psi / 0 to 350 bar
pressure gauge to the ls port on the function
manifold.
2
Start the engine from the ground controls.
3
Press and release the rpm select button until
the engine changes to high idle.
4
Raise the secondary boom approximately
12 inches / 30 cm.
5
Place a 4 x 4 inch / 10 x 10 cm block on the
secondary boom rest pad. Lower the
secondary boom onto the block.
Crushing hazard. Keep hands
clear of the block when lowering
the primary boom.
6
Simultaneously push and hold the function
enable/high speed button and the secondary
boom down button. Observe the reading on
the pressure gauge. Refer to Specifications,
Hydraulic Specifications.
7
Turn the engine off. Use a wrench to hold the
relief valve and remove the cap.
90
8
Adjust the internal hex socket. Turn it
clockwise to increase the pressure or
counterclockwise to decrease the pressure.
Install the relief valve cap.
Tip-over hazard. Do not adjust
the relief valve higher than
specified.
9
Start the engine and repeat step to confirm
relief valve pressure.
10 Start the engine and raise the secondary boom
approximately 12 inches / 30 cm. Remove the
block and lower the secondary boom to the
stowed position.
11 Turn the engine off and remove the pressure
gauge.
September 2016