Secondary boom up/down and extend/retract
functions:
1
Turn the key switch to the off position.
2
Press and hold the enter button on the ground
control panel while turning the key switch to
platform controls. Hold the enter button for
approximately 5 seconds.
3
Press the minus button twice, then press the
enter button twice.
4
Use the scroll button to scroll through the
menu until DELETE SECONDARY BOOM
JOYSTICK DEFAULTS is displayed.
5
Press the plus button to select YES, then
press the enter button.
6
Do not start the engine.
7
Locate the secondary boom up/down and
extend/retract joystick.
8
Move the secondary boom up/down and
extend/retract joystick full stroke in the
up/extend direction and hold for 5 seconds,
then return to the center or neutral position.
9
Move the secondary boom up/down and
extend/retract joystick full stroke in the
down/retract direction and hold for 5 seconds,
then return to the center or neutral position.
Result: The alarm at the ground controls
should sound for a successful calibration.
Part No. 1268556
Platform Controls
Primary boom extend/retract functions:
1
Turn the key switch to the off position.
2
Press and hold the enter button on the ground
control panel while turning the key switch to
platform controls. Hold the enter button for
approximately 5 seconds.
3
Press the minus button twice, then press the
enter button twice.
4
Use the scroll button to scroll through the
menu until DELETE PRIMARY BOOM
EXTEND/RETRACT JOYSTICK DEFAULTS
is displayed.
5
Press the plus button to select YES, then
press the enter button.
6
Do not start the engine.
7
Locate the thumb rocker switch on top of the
primary boom/turntable rotate joystick.
8
Move the primary boom extend/retract thumb
rocker switch full stroke in the extend direction
and hold for 5 seconds, then return to
thecenter or neutral position.
9
Move the primary boom extend/retract thumb
rocker switch full stroke in the retract direction
and hold for 5 seconds, then return to the
center or neutral position.
Result: The alarm at the ground controls
should sound for a successful calibration.