Service and Repair Manual
Platform Components
5
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Proceed to step 6.
Result: The alarm is sounding. The platform
overload indicator light is flashing at the
platform controls and "PLATFORM
OVERLOAD" should is displayed on the LCD
screen at the ground controls. Slowly tighten
the load spring adjustment nut in a clockwise
direction in 10° increments until the overload
indicator light turns off, and the alarm does not
sound. Proceed to step 8.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
34
6
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Slowly loosen the load spring
adjustment nut in a counterclockwise direction
in 10° increments until the overload indicator
light flashes at both the platform and ground
controls, and the alarm sounds. Proceed to
step 7.
Result: The alarm should be sounding. The
platform overload indicator light should be
flashing at the platform controls and
"PLATFORM OVERLOAD" should be
displayed on the LCD screen at the ground
controls. Repeat this procedure beginning with
step 5.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator lights and alarm
responds.