This table lists the various screens and menu options of the operating software. Some display menus are for
informational purpose only, while others can be used to change the machine operating parameters.
Tip-over hazard. Calibration and parameter settings must be completed by a person
trained and qualified on the repair of this machine. Failure to properly calibrate or set
parameters could cause the machine to tip over resulting in death or serious injury.
Note: The key switch must be in the off position before entering the programming mode.
Note: Use the following chart to identify the description of each LCD screen control button used in this
procedure.
Plus
Activation of the enter or previous buttons scrolls through the screens. To change parameter values or
select a setting, use the plus button (to increase or scroll forward) and the minus button (to decrease or
scroll backwards). Then press the enter button to save the new value to memory. An audible beep will
indicate a save to memory. Use the enter and previous buttons to scroll to the
button to change to
YES
Screen or Menu
Operator
Default
Part No. 1268556
Minus
and use the enter button to exit.
Procedure
Hourmeter (on power up)
Engine speed
Engine oil pressure PSI (English)
Engine oil pressure kPa (metric)
Engine temperature °F (Engiish)
Engine temperature °C (metric)
Primary boom angle to gravity
Turntable level sensor X° direction
Turntable level sensor Y° direction
Platform level sensor degree
Battery volts
Service and Repair Manual

Display Module

Previous
EXIT
Description
engine temp will not display
until temp is >100°F
engine temp will not display
until temp is >38°C
Enter
menu. Use the plus
Range or Selection
71