R O L A N D
Rev. 1.0

7.7.2 Program parameter 8: Teach-in

Possible teach-in items:
Missing: A teach-in has not been executed (only for NF)
Without: There is no teach-in existing, unit can be operated anyhow (only for FE)
OK: A teach-in was already executed
On: Performs a teach-in
Note: In order to enable measuring with a particular parameter set, a teach-in must
have been executed.
If no teach-in was executed or if a teach-in has to be repeated, the menu option "on" has to be selected.
Then the following two messages appears in succession:
Now a sheet with the nominal thickness must be presented to the sensor.
Attention: The sheet must contact the sensor without air gap. The position of the
sheet during teach-in must be identical to the position during normal operation.
Otherwise the measurement result could be faulty.
Then press the ENTER key.
During the teach-in procedure the following message is displayed:
Note: Fault messages are described in chapter 9.4 "Teach-in faults".
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
Program Par.:
System Param.:12
P12 LW:24-32mS/m
teach-in: ok
Program Par.:
System Param.:12
P12 LW:24-32mS/m
remove sheet !
Program Par.:
System Param.:12
P12 LW:24-32mS/m
attach sheet !
Program Par.:
System Param.:12
P12 LW:24-32mS/m
please wait
8
Picture: Status of Teach-in
8
Picture: Request to remove sheet for teach-in
8
Picture: Request to attach sheet for teach-in
8
Picture: Display during the teach-in for one sheet