System parameter 9: switching the password on / off.
Attention: If the password protection is de-activated, then all parameters can be
accessed at any time. This is recommended only for starting-up the system. For
normal operation the password protection should be activated.
System parameter 10: deactivating the external calibration.
Here the external calibration can be deactivated, which is possible via the interface with the signals
"Teach-in 0-sheet" and "Teach-in 1-sheet".
System parameter 11: setting the logic of the 0-sheet, 1-sheet and 2-sheet outputs.
Possible settings:
0 V: As depicted in the timing diagrams and the wiring diagrams
+24 V: The outputs 0-, 1- and 2-sheet are inverted, i.e. the respective signals in the timing diagrams
and wiring diagrams must be inverted.
Attention: The output ENABLE is not affected thereby.
System parameter 12: equipment diagnostics (Teach-in factors).
These parameters should not be changed by the user.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
System param.: 9
password: yes
System param.:10
ext. adjust:
System param.:11
output 0-1-2: 0V
Picture: Adjustment of the logic of the 0-sheet, 1-sheet and 2-sheet outputs
System param.:12
diagnos. factors
Picture: Switching the password on / off
no
Picture: Activate / deactivate the external calibration
Picture: Fixed systems parameter diagnostics