4.4 Mounting of the Sensor Switch Box SSBUDK10
Note: The Sensor Switch Box SSBUDK10 should be installed in locations where no
vibration exists and no additional heat is transferred into the system (even better
reduce the heat in the control unit). Furthermore, the Sensor Switch Box must be
installed such that it is always accessible and can be easily opened for service
purposes. During the operation the Sensor Switch Box and the sensors should be
under visual control of the operating personnel.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
25
59
95
130
165
Alle Maße sind in mm. Maßtoleranz: 0,2 mm.
All dimensions are in mm. Tolerance: ±0,2 mm.
200
230
250
Befestigungsbohrungen M4
Holes for mounting screws M4
238
250
±
Picture: Dimensions of sensor switch box SSBUDK10
B0048991