Roland udk20 Manual page 85

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

R O L A N D
Rev. 1.0
Program parameter 4: entering the nominal thickness of the sheet to be measured.
(Nominal thickness is normally the sheet thickness used for teach-in.)
Attention: A change of the nominal thickness deletes the values determined during
Teach-in. A new teach-in is necessary.
Possible values:
0.03 mm to 4 mm (.001 inch to 0.157 inch).
Program parameter 5: setting the percentage threshold of the upper limit.
Possible values:
100% to 150%. At the same time the absolute limit value is displayed.
Program parameter 6: setting the percentage threshold of the lower limit.
Possible values:
0% to 99%. At the same time the absolute limit value is displayed.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
Program Par.:
System Param.:12
P12 LW:24-32mS/m
nom.thick.:0.90mm
Program Par.:
System Param.:12
P12 LW:24-32mS/m
up:150%
Program Par.:
System Param.:12
P12 LW:24-32mS/m
low:50%
4
Picture: Setting the nominal thickness
5
1.350mm
Picture: Setting the upper limit
6
0.450mm
Picture: Setting the lower limit
Page 85