R O L A N D
Rev. 1.0
Description of the Teach-In procedure
For material
(system parameter 2)
Step 1:
Measured thickness
attach sheet and
will be displayed.
initiate Teach-In
Step 2:
Correct measured
Calibration
thickness to nominal
value (e.g. measured
with micrometer
screw).
Maximal possible
correction see I.
I:
depending on the set T-limit (system parameter)
a: 66% / 125%:
- possible upward correction of the displayed thickness:
max. 150 % of the indicated value
but not more than 125 % of the set nominal thickness, but not more than the
max. measurable thickness (depending on sensor; 4mm for PW42AGS)
- possible downward correction of the displayed thickness:
min. 80% of the indicated value
but not less than 66 % of the set nominal thickness
b: 33% / 142%:
- possible upward correction of the displayed thickness:
max. 300 % of the indicated value
but not more than 142 % of the set nominal thickness, but not more than the
max. measurable thickness (depending on sensor; 4mm for PW42AGS)
- possible downward correction of the displayed thickness:
min. 70% of the indicated value
but not less than 33 % of the set nominal thickness
II:
depending on the set T-limit (system parameter)
a: 66% / 125%:
- the ratio of measured to nominal value must be between 66% and 125%
b: 33% / 142%:
- the ratio of measured to nominal value must be between 33% and 142%
Attention!
For operation with „sequence 1+2" the values for sensor 1 and 2
may not deviate from each other for more than ± 20 %.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
local at unit
FE
NF / LM
Characteristic curve
will be determined.
Nominal value will be
displayed.
Correct measured
thickness to nominal
value (e.g. measured
with micrometer
screw).
Correction ± 20% of
nominal value.
via PLC (parallel)
FE
Measured thickness
Measured thickness
will automatically
will automatically
corrected to nominal
corrected to nominal
value.
Maximal corrected
Deviation will be
deviation see II.
internally corrected.
Page 89
NF / LM
value.