7.7.1 Program parameter 7: Zero adjust

Zero adjust is initiated with the ENTER key. If no zero adjust was executed or if it has to be repeated, the
menu option "on" has to be selected.
Then the following message appears (with version 2PW only):
Separate: All connected sensors must be zero adjusted individually, each sensor is addressed
individually for yes or no.
Common: All sensors are zero adjusted at the same time.
In any case the zero adjust continues with the following message, requesting to remove the sheet:
After having the sheet removed, press the ENTER key. Then the following message appears during the zero
adjust:
Note: Fault messages messages are described in the chapter 9.3 "Zero adjust fault".
When the zero adjust is completed, the following message appears:
The zero adjust is now completed.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
Program Par.:
System Param.:12
P12 LW:24-32mS/m
zero adjust: off
Program Par.:
System Param.:12
P12 LW:24-32mS/m
remove sheet !
Program Par.:
System Param.:12
P12 LW:24-32mS/m
please wait
Program Par.:
System Param.:12
P12 LW:24-32mS/m
zero adjust:done
7
Picture: Status of zero adjust
7
Picture: Removing sheet for zero adjust
7
Picture: Display during zero adjust
7
Picture: Zero adjust successfully completed