Roland udk20 Manual page 82

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

R O L A N D
Page 82
System parameter 13: equipment diagnostics (W-diagnosis)
Note: The settings of the current program will be taken over as default settings.
The ENTER key leads to the following menu item:
Here the conductivity range for the diagnosis is set.
Extra: = slightly magnetical NF material
FE = magnetical steel
For NF material the conductivity range is shown.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
Here the thickness range for the diagnosis is set.
With the ENTER key and UP/ DOWN keys all ranges can be selected.
The ENTER key will exit the section.
The UP key leads to the following menu item:
Here the value of the analog-digital converter and the thickness (calculated from the characteristic curve)
are shown (without teach-in correction). For 2PW units the values for both sensors will be shown.
The UP key leads to the following menu item:
Here the used frequency and gain is shown.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
System param.:13
W-diagnostics
System param.:13
LW: 24-32mS/m
System param.:13
DB: <4.00mm
System param.:13
AD:2048 D:1.22mm
Picture: Indicating the thickness calculated from the characteristic curve
System param.:13
F=250Hz
Picture: Fixed systems parameter diagnostics
Picture: Setting the conductivity range for the dignosis
Picture: Setting the thickness range for the diagnosis
V=157
Picture: Indicating the frequency and gain
B0048991