6.1.3.2 Continuous measurement

The control unit measures continuously as long as the signal "Measurement Start" is switched to HIGH.
If the signal "Measurement Start" is switched to LOW, the measurement is aborted and the last measuring
result is frozen until a new cycle is initiated.
Enable
OUT 0
Measurement
IN 1
Start
IN 2-8
0-Sheet
OUT 3
1-Sheet
OUT 2
2-Sheet
OUT 1
1
*t
: The system reaction time is the time required by the unit in order to issue the result to the output after
S
the signal "Measurement Start" has been recognized (see sensor data for ferrous and non-ferrous material,
chapter 2.2 and 2.3).
*t
: Additional recovery time of 0.5 seconds (for FE material)
p
Attention: In the relay output version the status of the outputs appears delayed
(<10 ms) due to the switching time of the relays.
Note: High Level at the outputs means relay closed respectively opto coupler low
resistant. Low Level at the outputs means relay open respectively opto coupler high
resistant.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
min. 30ms
max. 30ms
2
4
3
t
*
t
+ t
*
S
p
S
5
min. 30ms
Page 67
6
7