R O L A N D
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
Page 22
B0048991
"CLR parameter (Clear Program Parameter)"
Deletes all program parameters. For doing so, the parameter needs to be set to "yes". Executing the
command requires several minutes, since the program memory will completely cleared. All program
parameters will be reset to the default values and existing teach-in data will be deleted. Using this
function only makes sense if a unit is to be newly used for another machine.
"Password yes/no"
Switches the password request on/off. If the password request is set "on", the system / program
parameters can only be changed after the password has been entered.
"External Alignment"
Sets whether an external teach-in / zero adjust is to be possible. If "yes" is set, the PLC can trigger the
procedure via the inputs "Teach-In 0-, 1-sheet". Default setting is "no".
The external alignment may only be performed under supervision of an operator.
"Output level"
Sets the output voltages for outputs 0-,1-,2-sheet führen. Default setting is 0 V DC.
"Diagnosis factor"
Diagnosis of the factors located during the Teach-In. No default setting.
"W-Diagnosis"
Diagnosis of the measuring values for NF material type. No default setting.
"UDK20-PR-S-(1)"
"SV:xx HV:xx"
Identification of unit. Needs to be at hand for telephone support.
"Version"
Indication of the version of the unit. Factory setting, do not change !
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33