System parameter 3: specifying the number of sensors connected.
Selection for 2PW units: 1/2 sensors; selection for SSB: 1, 2, 3, 4 sensors.
Attention: If a particular configuration is changed, all stored program parameters are
deleted. Then for all types of material the nominal thicknesses must be entered
again and the teach-in executed.
System parameter 4: specifying the dimensions (mm / inch).
If the measurement dimensions are changed, then the sheet metal thicknesses of the stored programs
parameter are converted into the new dimension.
System parameter 5: setting the measuring mode.
The following measuring modes are possible:
External continuous measurement: The system executes measurements, as long as the
"Measurement start" signal is applied via the external PLC input. For FE material the repetition time
of the measurement is 0.5 seconds; for NF and LM it is less than 0.085 seconds.
External single measuring: The system measures once if the "Measurement start" signal is applied
via the external PLC input. Each measurement must initiated separately. The hints in chapter 6.1.3.1
„timing diagram single measurement" must be abided by.
Demo mode: This mode of operation is intended for equipment demonstrations but not for the normal
process operation. The system executes measurements continuously. For FE material the repetition
time of the measurement is 1 second; for NF and LM it is less than 0.085 seconds.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
System param.: 3
number sensors:2
System param.: 4
dimension: mm
System param.: 5
mode: ext.cont.
Picture: Setting the number of sensors
Picture: Setting the dimension for the display
Picture: Setting the measuring mode