Technical Data Control Unit Udk20 - Roland udk20 Manual

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

ROLAND
Page 16

2.5 Technical data control unit UDK20

Operating voltage:
Power consumption:
Switch on current:
External Fuse:
Weight:
Ambient temperature:
Wall mount enclosure
Dimensions (without connected plugs):
Dimensions (with PG connected plugs):
Protection category:
Front panel enclosure
Dimensions:
Protection category:
Additional characteristics
255 parameter sets memory
Programming via push buttons
9 galvanically insulated optocoupler inputs 24 VDC with joint common
Specification:
-
min. switching voltage HIGH:
-
max. switching voltage HIGH:
-
min. switching voltage LOW:
-
max. switching voltage LOW:
4 potential free outputs with common positive supply voltage
Specification:
Relais version:
-
switching outputs:
-
max. switching voltage:
-
max. switching current:
-
max. switching capacity:
Opto coupler version:
-
switching outputs:
-
max. switching voltage:
-
max. switching current:
-
max. switching capacity:
Attention: With inductive load please use unloading diodes. Otherwise the signal output can be
damaged by voltage surges caused by switching off inductive loads.
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
24 VDC, +6V / -2 V
< 60 W (measuring mode < 60 W, standby mode < 10 W)
approx.: 10 A for 1 ms
5 A, slow-blow
approx.: 1.2 kg (2.65 lb)
0 - 50 °C (32 - 122 °F)
approx.: 205 x 140 x 80 mm
approx.: 8.07 x 5.51 x 3.15 inch
approx.: 205 x 220 x 80 mm
approx.: 8.07 x 8.66 x 3.15 inch
IP65
approx.: 180 x 180 x 70 mm
approx.: 7.09 x 7.09 x 2.76 inch
IP40 (inside), IP65 (front cover)
18 VDC
30 VDC
0 VDC
8 VDC
potential free relay opening contacts
250 V AC
1 A
240 W / 200 VA
emitter and collektor open
50 VDC
150 mA
100 mW
B0048991
(L x W x H)
(L x W x H)
(L x W x H)
(L x W x H)
(L x W x H)
(L x W x H)

Advertisement

Table of Contents
loading

Table of Contents