Test The Engine Idle Select - Genie S-40 Service Manual

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

October 2014
B-12

Test the Engine Idle Select

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
A properly operating engine idle select switch
is essential to good engine performance and safe
machine operation. There are two settings.
Foot switch activated low idle (turtle symbol)
allows the operator to control individual boom
functions. Drive functions will operate at low idle,
but at reduced performance.
Foot switch activated high idle (rabbit symbol)
should be used for normal machine operation. This
selection activates high idle only when the foot
switch is pressed down.
1 Pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2 Start the engine from the ground controls then
move the function enable toggle switch to the
high idle (rabbit symbol) position and hold in the
on position.
Result: The engine should change to high idle.
3 Release the function enable toggle switch.
Result: The engine should return to low idle.
Part No. 826364
4 Turn the key switch to platform controls.
5 Move the engine idle control switch to foot
6 Press down the foot switch.
7 Move the engine idle control switch to foot
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Section 3 • Scheduled Maintenance Procedures
CHECKLIST B PROCEDURES
switch activated high idle (rabbit and foot switch
symbol).
Result: The engine should not change to
high idle.
Result: The engine should change to high idle.
switch activated low idle (turtle symbol).
Result: The engine should change to low idle.
3 - 25