Error Source
ID
Name
Boom 1 Joystick
21
(primary boom up/
down)
Boom 1 directional
22
valves
Boom 1 flow
23
control valve
Boom 1 angle
24
sensor
Boom 2 Joystick
31
(secondary boom
up/down or
primary boom
extend/retract)
Boom 2 directional
32
valves
Part No. 826364
Error Type
ID
Name
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
31
Invalid setup
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Control System Fault Codes
Condition
Function is inoperative
until joystick is
calibrated. Alarm
sounds indicating
fault.
Function is inoperative
until joystick is
calibrated.
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Normal function except
threshold for one or both
directions is zero.
Reduced speed.
Initiate 1 second beep
of alarm.
Joystick is operating
outside of operational
limits. Alarm sounds
indicating fault.
Function is inoperative
until joystick is
calibrated.
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Section 5 • Fault Codes
Solution
Cycle power off,
then on and
problem should be
corrected.
Calibrate joystick
Cycle power off,
then on and
problem should be
corrected.
Cycle power off,
then on and
problem should be
corrected.
Calibrate valve
thresholds
Cycle power off,
then on and
problem should be
corrected.
Calibrate angle
sensor.
Cycle power off,
then on and
problem should be
corrected.
Calibrate joystick
Cycle power off,
then on and
problem should be
corrected.