Genie S-40 Service Manual page 156

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Section 5 • Fault Codes
Control System Fault Codes
Error Source
ID
Name
Boom 2 flow
33
control valve
Turntable rotate
41
joystick
Turntable rotate
42
directional valves
Turntable rotate
43
flow control valve
Drive enable
44
toggle switch
5 - 4
Error Type
ID
Name
12
Value too high
15
Value too low
17
Not calibrated
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
21
Fault
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Condition
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Normal function
except threshold for
one or both directions
is zero.
Joystick is operating
outside of operational
limits. Alarm sounds
indicating fault.
Function is inoperative
until joystick is
calibrated.
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Valve is operating
outside of operational
limits. Alarm sounds
indicating fault.
Normal function
except threshold for
one or both directions
is zero.
Drive enable function
is inoperative.
February 2014
Solution
Cycle power off,
then on and
problem should be
corrected.
Calibrate valve
thresholds
Cycle power off,
then on and
problem should be
corrected.
Calibrate joystick
Cycle power off,
then on and
problem should be
corrected.
Cycle power off,
then on and
problem should be
corrected.
Calibrate valve
thresholds.
Cycle power off,
then on and
problem should be
corrected.
Part No. 826364

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45 traxS-45

Table of Contents