Section 4 • Repair Procedures
PLATFORM COMPONENTS
S-40 Models:
2 Tag, disconnect and plug the hydraulic hoses
from the platform rotator. Cap the fittings on the
rotator.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
S-45 Models:
3 Tag and disconnect the hydraulic hoses from
the "V1" and "V2" ports on the counterbalance
valve manifold located on the platform rotator
and connect them together using a connector.
Cap the fittings on the manifold.
4 Support the platform leveling arms and platform
mounting weldment with an appropriate lifting
device, but do not apply any lifting pressure.
4 - 10
All Models:
5 Remove the six mounting bolts from the
6 Support the platform rotator with an appropriate
7 Support the platform leveling slave cylinder.
8 Remove the pin retaining fasteners from both
9 Use a soft metal drift to drive both pins out, then
S-40 • S-45 • S-40 TRAX • S-45 TRAX
platform mounting weldment. Remove the
center bolt and slide the platform mounting
weldment off of the platform rotator.
Crushing hazard. The platform
mounting weldment could become
unbalanced and fall if it is not
properly supported.
lifting device. Do not apply any lifting pressure.
Protect the cylinder rod from damage.
the slave cylinder rod-end pivot pin, and the
rotator pivot pin.
remove the platform rotator from the machine.
Crushing hazard. The platform
rotator could become unbalanced
and fall if it is not properly
supported.
February 2014