Code
Description
601
Flash checksum invalid
604
RAM failure
606
COP failure
615
Start relay coil open
616
Start relay control ground short
617
Start relay coil short to power
627
Fpump relay coil open
628
FPump motor loop open or high-side
shorted to ground
628
Fpump relay control ground short
629
FPump motor high-side shorted to power
629
Fpump relay coil short to power
642
5VE1 low voltage
643
5VE1 high voltage
650
MIL open
652
5VE2 low voltage
653
5VE2 high voltage
685
Relay Coil Open
686
Relay Control ground short
687
Relay coil short to power
1111
Fuel rev limit
1112
Spark rev limit
1121
FPP1/2 simultaneous voltages out of range
Part No. 826364
Code
1122
1151
1152
1153
1154
1155
1156
1157
1158
1161
1162
1163
1164
1165
1166
1171
1172
1173
1174
1175
1176
For further engine fault code troubleshooting and
diagnostic information, refer to the Ford MSG-425/
Ford DSG-423 EFI Diagnostic Manual (EDI part
number 1080030).
Ford MSG-425/DSG-423 EFI Diagnostic Manual
Genie part number
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Section 5 • Fault Codes
Ford MSG-425 Engine Fault Codes
Description
FPP1/2 do not match each other or the IVS
CL high LPG
CL low LPG
CL high NG
CL low NG
CL high gasoline bank1
CL low gasoline bank1
CL high gasoline bank2
CL low gasoline bank2
AL high LPG
AL low LPG
AL high NG
AL low NG
LPG cat monitor
NG cat monitor
Megajector delivery pressure
higher than expected
Megajector delivery pressure
lower than expected
Megajector comm lost
Megajector voltage supply high
Megajector voltage supply low
Megajector internal actuator fault detection
162067