SPN = Suspect Parameter Number / FMI - Failure Mode Identifier / KWP = Keyword Protocol
SPN
FMI KWP
100
0
734
High oil pressure; warning
threshold exceeded
100
0
735
High oil pressure; shut off
threshold exceeded
100
1
736
Low oil pressure; warning
threshold exceeded
100
1
737
Low oil pressure; shut off
threshold exceeded
100
3
732
Sensor error oil pressure; signal
range check high
100
4
733
Sensor error oil pressure
sensor; signal range check low
102
2
88
Charged air pressure above
warning threshold
102
2
89
Charged air pressure above
shut off threshold
102
4
777
Sensor error charged air
press.; signal range check low
105
0
996
High charged air cooler
temperature; warning
threshold exceeded
105
0
997
High charged air cooler
temperature; shut off
threshold exceeded
105
3
994
Sensor error charged air
temperature; signal range
check high
105
4
995
Sensor error charged air
temperature; signal range
check low
Part No. 826364
Description
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Deutz D 2.9 L4 Engine Fault Codes
SPN
FMI KWP
108
3
412
Sensor error ambient air
press.; signal range check high
108
4
413
Sensor error ambient air
press.; signal range check low
110
0
98
High coolant temperature;
warning threshold exceeded
110
0
99
High coolant temperature; shut
off threshold exceeded
110
3
96
Sensor error coolant
temp.; signal range check high
110
4
97
Sensor error coolant
temp.; signal range check low
111
1
101
Coolant level too low
132
11
1
Air flow sensor load correction
factor exceeding the maximum
drift limit; plausibility error
132
11
2
Air flow sensor load correction
factor exceeding drift limit;
plausibility error
132
11
3
Air flow sensor low idle
correction factor exceeding the
maximum drift limit
132
11
4
Air flow sensor load correction
factor exceeding the maximum
drift limit
157
3
877
Sesnor error rail pressure;
signal range check high
157
4
878
Sensor error rail pressure;
signal range check low
Section 5 • Fault Codes
Description
5 - 11