4 Using a suitable lifting device, place a test
weight equal to that of the available capacity at
one of the locations shown.
Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-4, How to Calibrate the Platform
Overload System (if equipped).
Illustration 1
5 Carefully move the test weight to each
remaining location. Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-4, How to Calibrate the Platform
Overload System (if equipped).
Part No. 826364
6 Using a suitable lifting device, place an
Note: There may be a 2 second delay before the
overload indicator lights flash, the alarm sounds
and the engine shuts off.
7 Using a suitable lifting device, remove the test
Note: There may be a 2 second delay before the
overload indicator lights flash, the alarm sounds
and the engine shuts off.
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
additional 50 lbs / 23 kg of weight onto the
platform.
Result: The alarm should sound and the engine
should shut off. The platform overload indicator
lights should be flashing at both the ground and
platform controls.
Result: The alarm does not sound, the engine
does not shut off and the platform overload
indicator lights are not flashing. Calibrate the
platform overload system. Refer to Repair
Procedure 2-4, How to Calibrate the Platform
Overload System (if equipped).
weights, restart the engine and carefully move
the test weights to each remaining location on
the platform. Refer to Illustration 1.
Result: The alarm should sound, the engine
should shut off and the platform overload
indicator lights should be flashing at both the
ground and platform controls.
Result: The alarm does not sound and the
platform overload indicator lights are not
flashing. Calibrate the platform overload
system. Refer to Repair Procedure 2-4, How to
Calibrate the Platform Overload System (if
equipped).